Euchner 098942E | CES-AR-C01-CH-SA : Non Contact Safety Switch
The CES-AR-C01-CH-SA is a Non Contact Safety Switch that provides enhanced safety in machinery operations.
Request a quote
| Attribute | Value |
|---|---|
| Rated insulation voltage Ui: | 75 V(Tested up to 75 V by employers’ liability insurance association) |
| Rated impulse voltage Uimp: | 1.5 kV |
| Connection Type: | M12 plug connector, 8-pin |
| Installation Orientation: | any |
| Degree of protection: | IP67 |
| Ambient temperature: | -20 … +55 °C |
| Item designation: | CES-AR-C01-CH-SA |
| Gross weight: | 0,191kg |
| ECLASS: | 27-27-24-03 Safety-related transponder switch |
| EMC protection requirements: | Acc. to EN IEC 60947-5-3 |
| Risk time according to EN 60947-5-3: | max. 260 ms |
| Risk time according to EN 60947-5-3, extension for each additional device: | max. 5 ms |
| Safety Class: | III |
| Degree of contamination (external, according to EN 60947-1): | 3 |
| Output Type: | Semiconductor outputs, p-switching, short circuit-proof |
| Rated Conditional Short-circuit Current: | max. 100 A |
| Discrepancy time: | max. 10 ms |
| Off-state Current Ir: | max. 0.25 mA |
| Test Pulse Duration: | max. 1 ms |
| Ready Delay: | 10 s |
| Switching frequency: | max. 1 Hz |
| Mounting distance: | min. 40 mm |
| Shock And Vibration Resistance: | Acc. to EN IEC 60947-5-3 |
| Notices For UL Approval: | Operation only with UL Class 2 power supply or equivalent measures |
| Switch-on Distance: | 19 mm(for non-flush mounting; assembly) |
| Secured Switch-off Distance Sar: | max. 45 mm(for non-flush mounting; assembly) |
| Secured switching distance sao: | min. 10 mm(for non-flush mounting; assembly) |
| Switching hysteresis: | 1 … 3 mm(for non-flush mounting; assembly) |
| Product Number | Variant Description |
|---|---|
| CES-AR-C01-CH-SA : Non Contact Safety Switch | CES-AR-C01-AH-SA : Non Contact Safety Switch |
| CES-AR-C01-CH-SA : Non Contact Safety Switch | CES-AR-C01-CH-SA-116322 : Ces In Reihe – Multicode |