Encoder Cable SAFE HTL ENCODER CABLE-M23CKW-PUR-015 | R1.450.9310.0
Safe HTL Encoder, SIL3, PLe, Hollow shaft, Size 58mm, Aluminium, 14 mm shaft diameter, Power supply 11-30V, digital HTL output (AA/, BB/, ZZ/) , 1024ppr, M23, 12 pins, Counter-Clockwise wiring, Radial
Request a quote
| Attribute | Value |
|---|---|
| ECLASS 11: | 27272500 |
| ECLASS 8.1: | 27272590 |
| ETIM 9.0: | EC001486 |
| ETIM 8.0: | EC001486 |
| ETIM 7.0: | EC001486 |
| ETIM 6.0: | EC001486 |
| ETIM 5.0: | EC001486 |
| ROHS conformity status: | Compliant |
| REACH-SVHC conformity status: | Compliant |
| Housing material: | Die-cast zinc |
| Weight: | 280g |
| Degree of protection (IP): | IP65 |
| Short-circuit Protective Device: | Yes |
| Category (ISO 13849-1): | 4 |
| PL (ISO 13849-1): | Level e |
| SILCL(IEC 62061): | SIL3 |
| PFHd(High demand mode): | 7.53E-10 1/h |
| HFT: | 1 |
| TM: | 20a |
| Nominal voltage: | 24V |
| Operating voltage min.: | 11V |
| Operating voltage max.: | 30V |
| Galvanic Isolation: | No |
| Rated Current: | 100mA |
| Ambient temperature min.: | -20°C |
| Ambient temperature max.: | 85°C |
| Storage temperature / transport min.: | -20°C |
| Storage temperature / transport max.: | 85°C |
| Standards: | IEC 61508, IEC 13849-1, IEC 61800-5-2, IEC 62061 |
| PFDd(Low demand mode): | 0.000066 |
| DC: | 0.99 |
| Mttfd: | 1515a |
| Shaft material: | AISI 303 stainless steel |
| Bearing type: | Series 6803 – sealed |
| Mechanical life time: | >24*10^9 rotations/ 100000 hours |
| Output signal: | Digital HTL-Signal (11-30V DC) |
| Pin coding: | A,A/,B,B/ for safety incremental Pulses |
| Color-coding encoder cable: | Agrey,A/pink,Bbrown,B/green,Ored,O/black,+Vblue and green/brown, 0Vwhite und white/green |
| Resolution: | 1024 ppm |
| Reverse Polarity Protection: | Yes |
| PFD avg. speed monitoring for 40°C: | 0.000066 |
| PFH speed monitoring for 40°C: | 0.000000000753 |
| MTTFd speed monitoring for 40°C: | 1515 |
| DCavg speed monitoring for 40°C: | 0.99 |
| Mission time speed monitoring for 40°C: | 20a |
| PFD avg. speed monitoring for 80°C: | 0.000297 |
| PFH speed monitoring for 80°C: | 0.000000000753 |
| MTTFd speed monitoring for 80°C: | 336 |
| DCavg speed monitoring for 80°C: | 0.99 |
| Mission time speed monitoring for 80°C: | 20a |
| PFD avg. position monitoring for 40°C: | 0.000066 |
| PFH position monitoring for 40°C: | 0.000000000753 |
| DCavg position monitoring for 40°C: | 0.99 |
| Mission time position monitoring for 40°C: | 20a |
| PFD avg. position monitoring for 80°C: | 0.000297 |
| PFH position monitoring for 80°C: | 0.00000000339 |
| DCavg position monitoring for 80°C: | 0.99 |
| Mission time position monitoring for 80°C: | 20a |
| PL category: | PLe/Kat4 |