Idem 114130: MPC 1NC Cable Right QC M8 4way with LED | Non-Contact Safety Switches
“Reliable, non-contact safety switch using coded magnetic technology.”
Request a quote
| Attribute | Value | 
|---|---|
| Approvals: | TUV, cULus | 
| Coding Level according to EN ISO 14119: | Low | 
| Technology: | Coded Magnetic, Hall effect | 
| Housing Material: | Red, Polyester | 
| Normally Closed Contacts: | Up to 2 N/C Safety (When the Guard is Closed) | 
| Normally Open Contacts: | Up to 1 N/O Auxiliary (When the Guard is Closed) | 
| Switching Distance: | Sao 8mm / Sar 20mm | 
| Response Time (OFF): | 60ms Maximum | 
| Tolerance to Misalignment: | 5mm in any Direction from 5mm Setting Gap | 
| Indication: | Green LED when Guard is Closed | 
| Connectivity: | 2m, 5m, 10m, M12 QC | 
| Length: | 41mm | 
| Width: | 26mm | 
| Height: | 13mm | 
| IP Rating: | IP67 | 
| Ambient Temperature: | -25 … +80 °C | 
| Storage Temperature: | -25 … +80 °C | 
| Power Consumption: | 25mA Max. | 
| Maximum Switched Current (Outputs): | 200mA (Minimum Internal Resistance 8.5ohms) | 
| Switching Frequency: | 1.0 Hz Maximum | 
| Approach Speed: | 200mm/m. to 1000mm/s. | 
| Cable: | PVC 6mm O.D. Conductors 0.25 sq.mm | 
| ISO 13849-1: | Up to PLe Category 4 (if both channels are used with a PLe control device) | 
| Pfhd: | 2.6 x 10-10 (1/h) | 
| Proof Test Interval (life): | 20 years | 
| Mttfd: | 866 years | 
| UL Info: | Type 1 Enclosures. Maximum temperature 50ºC plastic versions, 70ºC S/Steel versions. Maximum output 24V.dc 100mA. Powered by Class 2 or equivalent. | 
| Product Number | Variant Description | 
|---|---|
| 114131 | MPC 1NC Cable Left QC M8 4way with LED | 
 
	 
								 
								