Idem 414102: BMF-U 10M | Non-Contact Safety Switches
“Non-Contact RFID Safety Interlock Switch for electrical security.”
Request a quote
| Attribute | Value |
|---|---|
| Approvals: | TUV, cULus |
| Coding Level according to EN ISO 14119: | M = Medium / U = High |
| Technology: | RFID |
| Housing Material: | 316 Grade Stainless Steel |
| Normally Closed Contacts: | Up to 2 N/C Safety (When the Guard is Closed) |
| Normally Open Contacts: | Up to 1 N/O Auxiliary (When the Guard is Closed) |
| Switching Distance: | Sao 8mm / Sar 20mm |
| Tolerance to Misalignment: | 5mm in any Direction from 5mm Setting Gap |
| Indication: | Green LED when Guard is Closed |
| Connectivity: | 2m, 5m, 10m, M12 QC |
| Length: | 75mm |
| IP Rating: | IP67, IP69K |
| Ambient Temperature: | -25 … +55 °C (+105 °C for CIP/SIP Temporary Cleaning) |
| Storage Temperature: | -25 … +55 °C |
| Maximum Switched Current (Outputs): | 200mA (Minimum Internal Resistance 8.5ohms) |
| Switching Frequency: | 1.0 Hz Maximum |
| Approach Speed: | 200mm/m. to 1000mm/s. |
| Cable: | PVC 6mm O.D. Conductors 0.25 sq.mm |
| Mttfd: | 1100a |
| Diameter: | M18 x 1mm |
| Performance Level: | e (If both channels are used in combination with a SIL3/PLe control device) |
| Category: | Cat4 |
| Diagnostic Coverage DC: | 99% (high) |
| Enclosure: | Type 1 |
| Safety Integrity Level: | SIL3 |
| PFH (1/h): | 4.77E-10 (Corresponds to 4.8% of SIL3) |
| PFD: | 4.18E-05 (Corresponds to 4.2% of SIL3) |
| Proof Test Interval T1: | 20a |
| Maximum Temperature: | +50 °C |
| Supply: | 24VDC +/- 10% |
| Maximum Output: | 24V.dc 100mA |