Safety Light Curtain

24

Mar

What Are Safety Light Curtains?

How Does Safety Light Curtains Work

Emission of Infrared Beams

Safety light curtains operate by emitting invisible infrared beams across a protected area, usually between a transmitter and a receiver. These beams form a detection grid—when uninterrupted, the system allows the machine to run. If any beam is broken, such as by a hand entering the area, the system instantly detects it and stops the machinery.

For example, in a press machine, safety light curtains are mounted at the front of the hazard zone. If an operator’s hand crosses the beams, the interruption immediately triggers a stop command. This non-contact protective solution is ideal for environments requiring frequent access to dangerous areas, helping maintain safety without disrupting operations.

Detection and Response Mechanism

When an object breaks the beam field, the receiver detects the interruption and sends a stop signal to the safety controller or directly to the machine’s control system. This response typically occurs in milliseconds, which is critical for preventing injuries.

In applications like robotic assembly, safety light curtains protect operators during manual interactions. Once the area is clear and beams are restored, the machine can safely restart. Advanced features like muting and blanking allow certain

Key Components of Safety Light Curtains

Scanning Range

The scanning range defines the maximum allowable distance between the transmitter and receiver while maintaining effective detection. This is essential in larger machinery setups where access points span several metres. For instance, in automated storage or palletizing systems, a long scanning range ensures broad coverage without compromising safety. Choosing the correct range helps prevent blind spots and supports safe machine layout planning

This refers to the vertical coverage of the light curtain. A lower field height might be used for finger or hand detection, while higher fields are used for full-body detection in larger applications like robot cells or packaging lines. Selecting the right protective field height ensures all necessary areas are safeguarded, reducing the chance of accidental entry into hazardous zones.

Resolution is the distance between each beam. It determines the smallest object the curtain can detect. Common configurations include 14mm for fingers, 30mm for hands, and wider gaps for body detection. In precision settings, such as electronics manufacturing, high-resolution body detection are essential for detecting small tools or body parts entering danger zones.

Active systems use separate transmitter and receiver units, while passive systems integrate both into one unit paired with a reflector. Active systems are ideal for wider spaces and critical applications, while passive systems work well in tight areas. Choosing between active and passive light curtains depends on layout, scanning distance, and installation flexibility.

The scanning range defines the maximum allowable distance between the transmitter and receiver while maintaining effective detection. This is essential in larger machinery setups where access points span several metres. For instance, in automated storage or palletizing systems, a long scanning range ensures broad coverage without compromising safety. Choosing the correct range helps prevent blind spots and supports safe machine layout planning

This refers to the vertical coverage of the light curtain. A lower field height might be used for finger or hand detection, while higher fields are used for full-body detection in larger applications like robot cells or packaging lines. Selecting the right protective field height ensures all necessary areas are safeguarded, reducing the chance of accidental entry into hazardous zones.

Resolution is the distance between each beam. It determines the smallest object the curtain can detect. Common configurations include 14mm for fingers, 30mm for hands, and wider gaps for body detection. In precision settings, such as electronics manufacturing, high-resolution body detection are essential for detecting small tools or body parts entering danger zones.

Active systems use separate transmitter and receiver units, while passive systems integrate both into one unit paired with a reflector. Active systems are ideal for wider spaces and critical applications, while passive systems work well in tight areas. Choosing between active and passive light curtains depends on layout, scanning distance, and installation flexibility.

Safety Light Curtain Resolution

Essential Functions of Light Curtains





The restart interlock prevents machinery from automatically resuming after a safety breach. Instead, a manual reset is required once the area is cleared. This ensures that an operator has safely exited the hazard zone before operations continue. This is especially crucial for high-risk machines like injection moulders or presses, where unintended restarts could result in serious injury.

EDM monitors the state of safety relays or actuators to ensure they return to a safe position before restarting the machine. If a relay fails, EDM detects the fault and prevents the machine from running, helping maintain the integrity of the safety circuit.

Muting allows materials to pass through the beam field under controlled conditions without stopping the machine. Sensors detect incoming objects (like pallets) and temporarily disable specific beams, allowing passage while protecting operators. This function is common in conveyor lines where safety and uninterrupted flow are both critical.

Blanking disables specific beams to allow stationary objects within the curtain’s path. Fixed blanking disables known beam positions, while floating blanking allows limited movement within a predefined range. It’s ideal in environments where fixtures or tools are permanently positioned inside the detection zone, such as in press brakes.

Beam coding assigns a unique signal to each light curtain system, preventing interference when multiple curtains are installed close to one another. This ensures that only the correct receiver responds to its corresponding transmitter, reducing false triggers and downtime.

The restart interlock prevents machinery from automatically resuming after a safety breach. Instead, a manual reset is required once the area is cleared. This ensures that an operator has safely exited the hazard zone before operations continue. This is especially crucial for high-risk machines like injection moulders or presses, where unintended restarts could result in serious injury.

EDM monitors the state of safety relays or actuators to ensure they return to a safe position before restarting the machine. If a relay fails, EDM detects the fault and prevents the machine from running, helping maintain the integrity of the safety circuit.

Muting allows materials to pass through the beam field under controlled conditions without stopping the machine. Sensors detect incoming objects (like pallets) and temporarily disable specific beams, allowing passage while protecting operators. This function is common in conveyor lines where safety and uninterrupted flow are both critical.

Blanking disables specific beams to allow stationary objects within the curtain’s path. Fixed blanking disables known beam positions, while floating blanking allows limited movement within a predefined range. It’s ideal in environments where fixtures or tools are permanently positioned inside the detection zone, such as in press brakes.

Beam coding assigns a unique signal to each light curtain system, preventing interference when multiple curtains are installed close to one another. This ensures that only the correct receiver responds to its corresponding transmitter, reducing false triggers and downtime.

Benefits of Using Safety Light Curtains

Enhanced Safety Measures

Safety light curtains are essential in reducing the risk of injury in industrial environments. They create an invisible safety barrier that instantly stops machine operation when a person or object enters a hazardous zone. Unlike traditional guards, they offer unrestricted access and higher flexibility, making them perfect for dynamic workflows in automation, robotic cells, or high-speed packaging lines.

Prevention of Machinery Damage

Light curtains also protect machines by detecting obstructions early. If a tool, object, or limb enters the danger zone, the machine halts before impact, helping prevent equipment damage and costly repairs. This added layer of protection helps reduce unplanned maintenance and production delays.

Increased Operational Efficiency

By replacing bulky physical barriers with sensor-driven systems, light curtains improve access and speed up operations. Operators can interact with equipment more efficiently, and intelligent functions like muting and blanking help maintain productivity during material flow. This makes them ideal for applications where safety and speed must go hand-in-hand.

Machine Guarding using Safety Light Curtains

Choosing the Right Safety Light Curtain

Assessing Safety Levels

The selection process begins with evaluating the level of risk associated with the machine. Based on factors like injury severity and exposure frequency, machines are assigned safety integrity levels (SIL) or performance levels (PL). Higher-risk machines—like hydraulic presses—may require SIL 3 or PL e-rated safety light curtains to ensure compliance with international safety standards.

Determining Protected Height

The height of the light curtain must align with the area it needs to cover. For finger-level protection, a small height may be sufficient. For full-body detection at large entry points, taller curtains are necessary. Choosing the right height ensures complete coverage without leaving safety gaps.

Understanding Response Time

Response time is how quickly the curtain stops the machine after detecting a breach. Faster response times allow installation closer to the hazard, which is critical in space-constrained setups and high-speed lines. When calculating safe distances, always factor in both the machine’s stopping time and the curtain’s response time.

Evaluating Application Demands

Different environments have unique requirements. For dusty, wet, or outdoor applications, IP-rated rugged light curtains are essential. In clean, high-speed facilities, models with integrated muting or advanced diagnostics may be more appropriate. Understanding the application’s environment ensures optimal performance and long-term reliability.

Light Curtain Protected Height

Trends in Safety Light Curtains

Integration Improvements

Modern safety light curtains are designed for seamless integration with industrial control systems. With support for IO-Link Safety, PROFINET, and EtherCAT, they provide real-time diagnostics, faster wiring, and flexible configuration. This simplifies installations and enhances overall system intelligence—an essential feature for Industry 4.0-ready factories.

Enhanced Functionality

Today’s models go beyond simple stop functions. Many include built-in muting, alignment tools, diagnostic displays, and EDM. Some even support configurable detection zones, allowing partial access under certain conditions. These enhancements make light curtains more adaptable and efficient in fast-moving production environments.

Venus Light Curtain Offerings

ReeR: EOS4 X (14mm) | Safety Light CurtainReeR Admiral AX (14mm) | Safety Light CurtainReeR: EOS2 X (30mm) | Safety Light Curtain
ReeR: Floor Mounting Column (FMC) Bases for Safety Light CurtainsReeR: Brackets for Safety Light CurtainsReeR SAFEGATE M SG BOX | Connection Box for Light Curtains
ReeR SAFEGATE M SGO BOX | Wiring Connection Box for SAFEGATE Light CurtainsReeR: EOS4 X (30mm) | Safety Light CurtainReeR Admiral AX (30mm) | Safety Light Curtain
ReeR: EOS2 X (90mm) | Safety Light CurtainReeR: EOS4 X (90mm) | Safety Light CurtainReeR Admiral AX (90mm) | Safety Light Curtain
ReeR SAFEGATE SM | Safety Light Curtain with MutingReeR SAFEGATE SMO | Safety Light Curtain with Muting and Muting LampReeR SAFEGATE SMPO | Programmable Safety Light Curtain with Muting and Muting Lamp
ReeR SAFEGATE MA L2X | Safety Light Curtains Set with MutingReeR SAFEGATE MA T2X | Crossed Beams Safety Light Curtains Set with MutingReeR SAFEGATE MA L2P TRX V/G | Safety Light Curtains
ReeR SAFEGATE MA T4P TRX V/G | Safety Light Curtains Set with MutingReeR ADMIRAL AX LR 3B DB | Long Range Watertight Safety Light CurtainReeR JANUS – MJBOX MJB 1/2/3/4 | Wiring Connection Box for Safety Light Curtains
ReeR: EOS4 X (2,3 and 4 Beams) | Safety Light CurtainReeR: EOS2 X (2,3 and 4 Beams) | Safety Light CurtainReeR JANUS – ML TRX (2,3 and 4 beams) | Safety Light Curtain
ReeR JANUS – MT TRX (2,3 and 4 beams) | Safety Light CurtainReeR ADMIRAL AX LR WTH| Dual Beam Safety Light CurtainReeR AD SR0 Series | Safety Relay for Light Curtains
ReeR SR ONE Series | Safety Relay for Light CurtainsReeR SAFEGATE S | Safety Muting Light CurtainReeR SAFEGATE SO | Safety Muting Light Curtain with Automatic/Manual Restart
ReeR Measurement Light Curtains: MICRON MI ACReeR Measurement Light Curtains: MICRON MI 150 ACReeR Measurement Light Curtains: MICRON MI 300 AC
ReeR Measurement Light Curtains: MICRON MI 450 ACReeR Measurement Light Curtains: MICRON MI 600 ACReeR Measurement Light Curtains: MICRON MI 900 AC
ReeR Measurement Light Curtains: MICRON MI 750 ACReeR Measurement Light Curtains: MICRON MI 1050 ACReer: Vision VX, VXL, MXL Hand Protection (30mm) | Safety Light Curtain
Reer: Vision VX Body Protection (90mm) | Safety Light CurtainReeR AD SR0 | Safety Relay for Light Curtains – 1330902ReeR AD SR0A | Safety Relay for Light Curtains – 1330903
ReeR SR ONE | Safety Relay for Light Curtains – 1330900ReeR SR ONE C | Safety Relay for Light Curtains – 1330811ReeR SR ONE M | Safety Relay for Light Curtains – 1330904
ReeR SR ONE MC | Safety Relay for Light Curtains – 1330812ReeR Safety Light Curtain – EOS2 153XReeR Safety Light Curtain – EOS2 303X
ReeR Safety Light Curtain – EOS2 453XReeR Safety Light Curtain – EOS2 603XReeR Safety Light Curtain – EOS2 753X
ReeR Safety Light Curtain – EOS2 903XReeR Safety Light Curtain – EOS2 1053XReeR Safety Light Curtain – EOS2 1203X
ReeR Safety Light Curtain – EOS2 1353XReeR Safety Light Curtain – EOS2 1503XReeR Safety Light Curtain – EOS2 1803X
ReeR Safety Light Curtain – EOS4 153XReeR Safety Light Curtain – EOS4 303XReeR Safety Light Curtain – EOS4 453X
ReeR Safety Light Curtain – EOS4 603XReeR Safety Light Curtain – EOS4 753XReeR Safety Light Curtain – EOS4 903X
ReeR Safety Light Curtain – EOS4 1053XReeR Safety Light Curtain – EOS4 1203XReeR Safety Light Curtain – EOS4 1353X
ReeR Safety Light Curtain – EOS4 1503XReeR Safety Light Curtain – EOS4 1803XReeR Safety Light Curtain – EOS4 151X
ReeR EOS4 301X Safety Light Curtain – Industrial ProtectionReeR EOS4 451X Safety Light Curtain – Industrial ProtectionReeR Safety Light Curtain – EOS4 601X
ReeR Safety Light Curtain – EOS4 751XReeR Safety Light Curtain – EOS4 901XReeR Safety Light Curtain – EOS4 1051X
ReeR Safety Light Curtain – EOS4 1201XReeR Safety Light Curtain – EOS4 1351XReeR Safety Light Curtain – EOS4 1501X
EOS4 1801X Safety Light Curtain – Finger ProtectionReeR Safety Light Curtain – EOS2 155XReeR Safety Light Curtain – EOS4 155X
ReeR Safety Light Curtain – EOS2 309XReeR Safety Light Curtain – EOS4 309XReeR Safety Light Curtain – EOS2 459X
ReeR Safety Light Curtain – EOS4 459XReeR Safety Light Curtain – EOS2 609XReeR Safety Light Curtain – EOS4 609X
ReeR Safety Light Curtain – EOS2 759XReeR Safety Light Curtain – EOS4 759XReeR Safety Light Curtain – EOS2 909X
ReeR Safety Light Curtain – EOS4 1209XReeR Safety Light Curtain – EOS4 909XReeR Safety Light Curtain – EOS2 1359X
ReeR Safety Light Curtain – EOS2 1209XReeR Safety Light Curtain – EOS4 1059XReeR Safety Light Curtain – EOS2 1059X
ReeR Safety Light Curtain – EOS4 1509XReeR Safety Light Curtain – EOS2 1509XReeR Safety Light Curtain – EOS4 1359X
ReeR Safety Light Curtain – EOS4 1809XReeR Safety Light Curtain – EOS2 1809XReeR Safety Light Curtain – ADMIRAL AX 2B LR WTH
ReeR Safety Light Curtain – ADMIRAL AX 2B LR DB WTHReeR Safety Light Curtain – ADMIRAL AX 3B LR WTHReeR Safety Light Curtain – ADMIRAL AX 3B LR DB WTH
ReeR Safety Light Curtain – ADMIRAL AX 4B LR WTHReeR Safety Light Curtain – ADMIRAL AX 4B LR DB WTHReeR: EOS2 X Body Protection | Body-Detection Safety Light Curtain
JANUS – MJBOX MJB 1 | Wiring Connection Box for Safety Light CurtainsJANUS – MJBOX MJB 2 | Wiring Connection Box for Safety Light CurtainsJANUS – MJBOX MJB 3 | Wiring Connection Box for Safety Light Curtains
JANUS – MJBOX MJB 4 | Wiring Connection Box for Safety Light CurtainsJANUS – ML 2B TRX |Safety Light CurtainJANUS – ML 3B TRX |Safety Light Curtain
JANUS – MT 2B TRX |Safety Light CurtainDOLD Light curtain controller with selectable operating modesDOLD Light curtain controller
DOLD Safety module, light curtain Â